USUALLY SEGMENTED THE SAME DAY · REVIEWED WITH THE PATIENT · GUIDES AND IMPLANTS DESIGNED BY THE OPERATING SURGEON · THREE OUTPUTS →
AT A GLANCE
The whole page in one minute — the detail follows below.
WHO THIS IS FOR
Any case where an X-ray is not enough — deformity, bone loss, a failed replacement, anatomy a stock implant was never designed for — and routine joint replacements that benefit from a measured plan.
HOW YOU ARE ASSESSED
A fine-slice CT, taken at Macquarie Medical Imaging for Macquarie patients and usually segmented the same day; EOS alignment films where the whole leg matters; the model reviewed with you in the room.
THE OPTIONS
A measured plan for standard implants; patient-specific cutting guides designed by the surgeon; a custom 3D-printed titanium implant where nothing standard fits — all designed by Dr Alttahir himself.
THE COMMITMENT
The model is same-day; guides follow once the plan is agreed; a custom implant takes two to six weeks to design, manufacture and sterilise, plus the health fund’s ex-gratia approval, which the rooms arrange.
NEXT STEP
Call the rooms on (02) 8882 9011 or (02) 9602 1113. A GP referral is needed for the Medicare rebate. Complex cases are reviewed in the rooms or at the Complex Limb Reconstruction Clinic at Macquarie University Hospital.
WHY MOVE BEYOND 2D
WORKFLOW
WHAT THE PROCESS PRODUCES
WHERE IT’S USED
PELVIC DISCONTINUITY · SEVERE ACETABULAR BONE LOSS
TALAR COLLAPSE · FAILED ANKLE REPLACEMENT
A custom 3D-printed implant fills the bone defect in the talus and couples with a total ankle replacement, so the ankle is not fused. The subtalar and talonavicular joints are fused to the implant.
HTO · DFO · SUPRAMALLEOLAR CORRECTION
Cutting guides lock onto unique bone landmarks, defining the osteotomy plane and correction wedge precisely as planned.
DISCREPANCY AFTER TRAUMA, INFECTION, GROWTH ARREST
FEMORAL AND TIBIAL TORSION · DEROTATION OSTEOTOMY
A CT torsional profile of the whole limb, modelled in 3D, shows whether a kneecap that keeps dislocating is being pulled by rotation in the femur or tibia — and plans the derotation osteotomy that corrects it.
MASSIVE BONE LOSS · FAILED PREVIOUS REVISIONS
Dr Alttahir does the 3D planning himself: he segments the CT, plans the correction and designs the guide, rather than receiving a suggested plan from an engineering company.
WHO DOES WHAT, HERE
Surgeon assesses raw imaging.
Surgeon performs bone and implant segmentation in Mimics.
Surgeon designs cuts, corrections, implant position.
Same surgeon performs the surgery to the plan they built.
THE TOOLKIT
Materialise Mimics — DICOM segmentation, bone modelling, and implant extraction from CT data.
Implant design in 3‑matic and, occasionally, SolidWorks, with medical engineering partners completing the manufacturing CAD.
HONEST LIMITATIONS
Most cases don’t need a custom guide or implant
Lead time matters
Custom implants typically take 2–6 weeks to design, manufacture and sterilise. Truly urgent cases — acute fracture, acute infection — cannot wait for custom solutions. Standard implants are used instead.
Not all health funds cover custom implants
Planning is only as good as the scan
Soft tissue is not modelled fully
CT shows bone well, soft tissue poorly. MRI is added when ligament, cartilage or tendon information is essential. Even then, judgement in theatre remains decisive.
FOR REFERRERS
PLEASE INCLUDE
Recent CT scan of the affected region
All prior operative reports and imaging
Implant details if revision is being considered
Comorbidities relevant to anaesthesia and healing
Patient goals and functional limitations
SYDNEY ADVANCED ORTHOPAEDICS · (02) 8882 9011 · MACQUARIE · NORWEST · EAST SYDNEY
LIMB RECONSTRUCTION SERVICE NSW · (02) 9602 1113 · CAMPBELLTOWN
COMMON QUESTIONS
BEGIN
CALL THE ROOMS
MACQUARIE · NORWEST · EAST SYDNEY
CAMPBELLTOWN
This page provides general information about 3D surgical planning and custom implants and is not a substitute for individual medical advice. Custom implants are used in selected cases only, where standard implants cannot address the anatomy or bone loss. All implants used are TGA-regulated and manufactured by accredited facilities. Outcomes vary between patients. Diagrams are schematic and illustrative only. Advertising on this site complies with the AHPRA Guidelines for advertising a regulated health service.